Fayetteville · Hope Mills · Spring Lake · Cumberland County24/7
Technician holding a refrigerant gauge set with a yellow hose

Home › Guides › R-22, R-410A and R-454B

Fayetteville air conditioning repair

Which refrigerant does your air conditioner use?

Home systems use R-22, R-410A or R-454B depending on when they were made. The three are not interchangeable. The data plate on the outdoor unit names the one in yours.

  • Leaks found before any recharge
  • Refrigerant recovered, never vented
  • Free estimates

Open 24/7

Request AC service

Step 1 of 2: your contact details
Step 2 of 2: about the job

  • Free estimates
  • 24/7 service
  • Fayetteville and Cumberland County

How an AC repair works with us

  1. Send the form

    Your name and phone number first, then the address and what the system is doing.

  2. We call you back

    We ask a few questions about the system and set a time to come out.

  3. We find the fault

    We test the electrical parts, airflow, drain and refrigerant circuit instead of guessing.

  4. You get a free estimate

    We tell you what failed and what it costs before any repair starts.

  5. We fix it and test it

    The system runs through a full cooling cycle before we leave.

The estimate is free and you are under no obligation to book the repair.

Get a leak repair quote

How do the three compare?

R-22R-410AR-454B
Found inOlder systemsSystems from recent yearsThe newest systems
Still made in the U.S.?Not since January 1, 2020Being replaced in new equipmentIn current production
Can be swapped for another?NoNoNo

Can an R-22 system still be serviced?

It can. U.S. production and import of R-22 ended on January 1, 2020. Existing systems can keep running and be serviced with recovered, reclaimed or stockpiled R-22, and nobody is required to replace a working system (EPA: the phaseout of R-22).

What changes is the math on a big leak. With no new supply, a large recharge on an old system is often money better spent on replacement.

What about products sold as R-22a?

Stay away from them. The EPA says "R-22a" is a flammable blend and is not acceptable for home air conditioners. A system charged with it is a fire risk to you and to the next person who services it.

Why can't refrigerants be mixed or swapped?

Each one runs at different pressures and is matched to the compressor, the coils and the metering device. Putting one refrigerant in a system built for another damages the equipment. That is also why a new outdoor unit needs an indoor coil made for the same refrigerant. See AC installation and replacement.

R-22, R-410A and R-454B questions

Is it illegal to have R-22 in my air conditioner?
It is legal to own and run an R-22 system and to have it serviced. What ended on January 1, 2020 was U.S. production and import of new R-22. Service now relies on recovered, reclaimed and stockpiled refrigerant.
Can R-410A be put in an R-22 system?
It can't be added to an R-22 system. The two run at different pressures and are not interchangeable, so the equipment has to match the refrigerant. Topping off one with the other damages the system.
Is it legal to release refrigerant into the air?
Venting refrigerant is illegal under Section 608 of the Clean Air Act. When a system is opened or removed, the refrigerant is recovered into a cylinder first. That applies to old R-22 units being replaced as much as to repairs.

Have a leak checked

Send your name and phone number, then the address and what the system is doing. We take requests 24/7 and the estimate is free.

24/7

Step 1 of 2: your contact details
Step 2 of 2: about the job

Get a free estimate